Pump base plate, Brinefield site,
I.C.I. North Tees Works.
Client: I.C.I. Plc. Wilton Works, Middlesbrough.
Problem
The concrete / steel bed plate base on which the pump is bolted to is subject to brine
solution chemical attack causing extensive corrosion.
Solution
Prepare the surface area by grit blasting. Patch repair the corroded
areas with “Metset 15” rapid hardening, non shrink mortar. Spray apply
“Metflex” Multi Purpose Elastomeric Coating to nominal thickness of
2.0mm.
Result
An instant hard wearing coating providing protection against chemical
attack over dissimilar materials i.e. concrete and steel.
Containment Bund
Client: Chemoxy International Plc.
Problem
The concrete bund was cracked and leaking. Some areas were corroded
from chemical attack.
Solution
Prepare the surface by grit blasting, patch repair corroded areas with
Metset 15 mortar. Spray apply Metflex Multi Purpose Elastomeric Coating at
2.00mm incorporating slip resistant aggregate into top surface.
Result
A hard wearing, slip resistant, flexible membrane providing protection
against chemical attack and providing total containment for spillages etc.
Storage Tank, Templeborough Rolling Mills, Rotherham
Client: British Steel Plc.
Problem
The concrete water holding tank had developed a large number of cracks
and fissures causing the tank to leak.
Solution
Grit blast all internal surfaces of the tank to clean and prepare
substrate. Remove surplus grit and clean out all remaining rubbish. Spray
apply nominal 1.5mm thickness “Metflex” Elastomeric Coating. The base
of the tank was severely contaminated and as such could not be cleaned. A
geotextile membrane was mechanically fastened to the inner surface of the
tank wall and sprayed with Metflex to produce an insitu liner.
Result
An instant waterproof coating solving the leakage problem.
Containment Bund Austerfield Sub - Station
Client: Yorkshire Electricity.
Problem
Transformer Oil was leaking into the bund and due to cracking and
leakage around cable ducts and the general porous nature of the concrete
the oil was seeping out causing potential environmental problems.
Solution
Spray apply “Metflex” MultiPurpose Elastomeric Coating to a
thickness of 1.5mm totally encapsulating all items within the bund and
preventing leakage of the transformer oil.
Result
An instant hard wearing, waterproof, oil resistant, impermeable
coating that can be returned to service immediately after spraying.
Phosphoric Acid containment bund
Client: Arizona Chemicals - Birtley.
Problem
Phosphoric acid was leaking attacking the concrete and contaminating
the ground.
Solution
Spray Metflex 120 as a liner both protecting the concrete and
preventing damaging leakage
|