Technical Support

Physical properties of sprayed Metflex film

 

Property  Test Method  Result
Hardness  Shore A  80 - 85
Density    0.92g/cm + 0.3
Tensile strength  ASTM D412  12.0 Mpa. + 2.0
Elongation at break  ASTM D412  380% + 40
100% Modulus  ASTM D412  5.0 Mpa + 0.5
300% Modulus  ASTM D412  9.0 Mpa + 0.5
Tear Strength  ASTM D412  40.0 KN/m Max
Abrasion resistance  DIN 53516  150mm Max.
Taber Abrasion  1000g wt; H22 wheel  125mg/1000 Cycles
Pull off adhesion test wet concrete  BS EN 24624  1.2 Mpa.
Pull off adhesion test dry concrete  BS EN 24624  2.9 Mpa.
Pull off adhesion test dry clay pavior  BS EN 24624  2.9 Mpa.
Pull off adhesion test steel  BS EN 24624  5.8 Mpa.

 

NB. The use of a primer significantly increases these pull off values.

Dielectric strength (Resistivity) 5.7 KV @ 1000mu i.e. 4mm thickness required to resist 60,000 Volts.

Hydrostatic pressure resistance from behind the film applied to rough concrete 60 bar / 880 Psi.

Top
© Metflex Protective Coatings Ltd, 25 - 27 Glasgow Street, Thornaby, Teesside TS17 7AH, England
Tel: + 44 (0) 1642 606652 Fax: +44 (0) 1642 614258 E-mail: info@metflex.uk.com